000 03820nam a2200289Ia 4500
001 90915
003 FT7909
005 20251119144128.0
008 240822n 000 0 eng d
040 _erda
041 _aengtag
050 _aTK7871.85 A38 2024
082 _a.
100 _aKristianne V. Aguilar, John Francis M. Calvario, Ria Marion G. Japzon, Paul Andre S. Zaballero.
245 0 _aDevelopment of an integrated monitoring system for real-time electrostatic discharge checking and personal protective equipment compliance.
264 _a.
_b.
_cc2024
336 _b.
_atext
_2rdacontent
337 _30
_b.
_aunmediated
_2rdamedia
338 _30
_b.
_avolume
_2rdacarrier
505 _aABSTRACT: Electrostatic Discharge (ESD) poses a significant threat to the semiconductor industry, leading to premature failures of integrated circuits (ICs) and substantial financial losses. Currently, PPE usage relies solely on manual inspections, with no verification of proper wear, and real-time ESD alerts are provided only by wearable device LED indicators. This paper presents an integrated monitoring system combining Radio Frequency Identification (RFID) to check PPE completeness, Image Processing technology to verify proper PPE wear, targeting the ESD Category 3 garmet standard, and a real-time ESD checker to monitor body voltage discharge. The system includes M5stack Basic Core, YOLOv8 algorithm, and NodeMCU ESP32. The optimal detection distance for the RFID system was 0.75 meters, achieving precision, recall, and F1 scores of 100%, 73.33%, and 85%, respectively.For the image processing system, the optmal detection distance was 2 meters, yielding 100% precision, recall, and F1 scores, with a mean Average Precision (mAP) of 98%. The ESD checker demonstrated high accuracy and reliability, with a response time of 1 to 6 seconds, an operational capacity of 15 hours and 15 minutes, and a reliability rate of 92.28%. Mean voltages detected with and without ESD PPE were 48.87 V and 69.02 V (standing), and 71.32 V and 97.96 V (walking). This system effectively detects PPE compliance and monitors personnel’s voltage levels, ensuring safety in ESD-sensitive areas.
520 _aABSTRACT: Electrostatic Discharge (ESD) poses a significant threat to the semiconductor industry, leading to premature failures of integrated circuits (ICs) and substantial financial losses. Currently, PPE usage relies solely on manual inspections, with no verification of proper wear, and real-time ESD alerts are provided only by wearable device LED indicators. This paper presents an integrated monitoring system combining Radio Frequency Identification (RFID) to check PPE completeness, Image Processing technology to verify proper PPE wear, targeting the ESD Category 3 garmet standard, and a real-time ESD checker to monitor body voltage discharge. The system includes M5stack Basic Core, YOLOv8 algorithm, and NodeMCU ESP32. The optimal detection distance for the RFID system was 0.75 meters, achieving precision, recall, and F1 scores of 100%, 73.33%, and 85%, respectively.For the image processing system, the optmal detection distance was 2 meters, yielding 100% precision, recall, and F1 scores, with a mean Average Precision (mAP) of 98%. The ESD checker demonstrated high accuracy and reliability, with a response time of 1 to 6 seconds, an operational capacity of 15 hours and 15 minutes, and a reliability rate of 92.28%. Mean voltages detected with and without ESD PPE were 48.87 V and 69.02 V (standing), and 71.32 V and 97.96 V (walking). This system effectively detects PPE compliance and monitors personnel's voltage levels, ensuring safety in ESD-sensitive areas.
526 _aF